A backwater valve is a one-way valve on a basement drain that closes when the municipal sanitary sewer backs up. Ontario’s 2024 Building Code requires one to protect fixtures below the street or below the upstream sanitary manhole cover. A licensed plumber installs it under a permit, and the building permit drawings for a larger project show where it goes.

Prepared by Elmid Design Inc. · Reviewed by Hamid Akbari, P.Eng.
Free quote for basement plumbing drawings: tell us about the house and the work through our contact form, or call (647) 745-4507. We reply by email so you can send photos and any existing drawings.
Basement flooding from the sewer is different from water coming through a wall or a window well. When heavy rain overloads a combined or sanitary sewer, sewage can flow backwards up the house connection and out of the lowest drain in the house, usually a floor drain, a basement toilet or a laundry tub. A backwater valve is the device that blocks that reverse flow.
This guide explains what the Building Code says, how Toronto handles the permit and its subsidy, where the valve goes on basement plumbing drawings, and what the valve does not protect against. If your project is a wider basement renovation, our Toronto plumbing permit guide covers the rest of the plumbing permit.
What is a backwater valve?
A backwater valve is a device installed in a drain pipe that lets wastewater flow out of the house but closes when water tries to flow back in. Most residential valves use a flap or gate that floats shut when the sewer surcharges, and many have a clear lid so the plumber can inspect and clean it.
People also call it a sewer backup valve or sewer check valve. It is not a backflow preventer on the water supply, which protects drinking water; that device is covered in our guide to backflow permit drawings in Toronto.
While it is closed, fixtures upstream of it should not be used, because their water has nowhere to go, as City of Toronto guidance notes. Many owners add an alarm that sounds when it closes.
When does the Ontario Building Code require a backwater valve?
Under Article 7.4.6.4 of the 2024 Building Code, where a building drain or branch may be subject to backflow, a backwater valve is required on fixtures below the level of the adjoining street, or to protect fixtures below the upstream sanitary manhole cover when a residential building is served by a public sanitary sewer.
The 2024 Building Code is O. Reg. 163/24, in force since January 1, 2025. Article 7.4.6.4, “Protection from Backflow,” has five sentences. In plain terms:
- Sentence (1): a backwater valve that would prevent the free circulation of air must not be installed in a building drain or building sewer, except as Sentence (2) allows.
- Sentence (2): one may go in the building drain if it is a “normally open” design conforming to one of the listed CSA pipe standards and it serves not more than one dwelling unit.
- Sentence (3): where the building drain or a branch may be subject to backflow, one is needed on every fixture drain below street level, or to protect fixtures below the upstream sanitary manhole cover in a residential building on a public sanitary sewer.
- Sentence (4): where several fixtures on one storey share a branch, a single device on the branch can protect them.
- Sentence (5): foundation drains (subsoil drainage pipe) that drain into a sanitary system subject to surcharge must be connected so sewage cannot back up into them.
“May be subject to backflow” is a judgement about the site. In many GTA houses the basement floor drain sits below the street and below the upstream sewer manhole cover, so the question for most basements is not whether to protect the low fixtures but how.
Can a backwater valve go on the main building drain?
Yes, if it meets Sentence 7.4.6.4.(2): a normally open valve to the listed CSA standard, serving not more than one dwelling unit. Toronto’s permit guide adds that a valve designed to sit normally closed is prohibited in a building drain or building sewer, because it would stop air circulating in the drainage system.
A main-drain valve is the common choice in a single-family house: one device on the building drain, downstream of every basement fixture, protects the whole basement. The trade-off is that the whole house drains through it, so when it closes nobody should run water until the sewer level drops.
Branch or fixture valves protect only the fixtures behind them. They suit houses where upper floors should keep draining, where the main drain is hard to reach, or where the code limit on dwelling units applies. The table compares the two.
| Question | Main building drain valve | Branch or fixture valves |
|---|---|---|
| What it protects | Every fixture upstream of it, including upper floors | Only the fixtures connected to that branch or drain |
| Code condition | Normally open design to a listed CSA standard; serves not more than one dwelling unit | Required on each fixture drain, or one valve per branch where fixtures on a storey share it |
| When it closes | No fixture in the house should be used | Upper floors and unprotected branches keep draining |
| Number of devices | Usually one | One per branch or fixture drain below the backflow level |
| Access | Access cover in the slab above the valve | Access to each one |
What changes when a house has two dwelling units?
Sentence 7.4.6.4.(2) limits a building-drain valve to one dwelling unit, so in a house with a second unit the designer usually protects the basement fixtures with branch or fixture valves instead. Markham’s Builder Tip 108 shows this layout for multi-dwelling houses: smaller valves on the basement branches, none across the shared building drain.
The code does not state its reason, but in practice one valve on a shared drain would close for both households at once, and the upstairs household would have no warning that its sinks and toilets could back up into the other unit. Toronto’s permit page words the same limit as a building drain that “serves only one occupancy.”
Toronto’s standalone permit for this work covers houses with one or two dwelling units. Multi-unit and non-residential buildings need a standalone drain permit with the submission documents listed in the City’s plumbing and drain permit guide. For the wider permit package of a second unit, see secondary unit permit drawings in the GTA.
Do you need a permit to install a backwater valve in Toronto?
Yes. Toronto issues a standalone drain permit for a backwater valve in a house with one or two dwelling units, applied for online, and no plans are required for those houses. The valve must be inspected before it is covered. Multi-unit and non-residential buildings follow the standalone plumbing and drain permit guide instead.
Other GTA municipalities run their own permit routes. Markham’s Builder Tip 108 (updated to the 2024 Building Code, January 1, 2025) says backwater valves are required in flood-prone zones for new houses, renovations that affect the plumbing, and new dwelling units in basements. Check the local building department before work starts.
If the device is part of a bigger project, such as a new basement bathroom, an addition or a second unit, it is normally shown on that project’s permit drawings rather than applied for on its own.
When does a backwater valve appear on plumbing drawings?
A backwater valve is shown on plumbing drawings when it is part of a larger permit: a new house, a basement renovation that adds or moves fixtures, a second unit, an addition with below-grade plumbing, or a multi-unit or commercial building. For a valve alone in a Toronto house, the City requires no plans.
The drawings record which fixtures are below the backflow level and how they are protected, for the plans examiner, the plumber and the inspector. One added after the floor is finished is harder to place well.
What do plumbing drawings show for a backwater valve?
Plumbing drawings show the valve’s location on the basement plan, its type (a normally open main-drain type or a branch type), the pipe size, the fixtures it protects, the access cover in the floor, and how the foundation drains and any sump connect. Riser diagrams show which fixtures drain through the valve and which bypass it.
A clear drawing set for a basement usually includes:
- Basement drainage plan: building drain route to the foundation wall, the device symbol and tag, cleanouts and floor drains.
- Fixture list below the backflow level: floor drain, toilet, shower, laundry, sink, and any sewage ejector or sump.
- Schedule or note: normally open design, the CSA standard it conforms to, pipe size, and an alarm if the owner wants one.
- Access: an access cover or clean-out box in the slab so it can be inspected and cleaned; it is never buried under finished flooring.
- Foundation drain connection: weeping tile to a sump or to the sewer, arranged so sewage cannot back up into it (Sentence 7.4.6.4.(5)).
- Riser or isometric diagram: which stacks and branches drain through the valve, and which upper-floor fixtures bypass it in a branch layout.
Where should a backwater valve be located in a basement?
A main-drain valve is usually placed on the building drain inside the foundation wall, downstream of every basement fixture it must protect, with an access cover in the floor above it. Branch valves sit on the branch serving the low fixtures. Either way, the valve must stay reachable for inspection, cleaning and the manufacturer’s maintenance.
Practical points the designer checks on site or from existing drawings:
- The depth and route of the existing building drain, and whether any basement fixture joins it downstream of the proposed valve location, which would leave that fixture unprotected.
- Clearance for the body and its lid, and room to open it, away from walls, stairs and future cabinets.
- The position of the cleanout, so the sewer can still be rodded through or beside it.
- Floor finishes: the access cover is planned with the flooring so it stays visible and removable.
Toronto’s subsidy rules add a site rule of their own: request the inspection once installation is complete and do not enclose or cover the device before the inspection is done.
How do weeping tiles and sump pumps work with a backwater valve?
Foundation drains (weeping tiles) that discharge into a sanitary sewer subject to surcharge must be connected so sewage cannot back up into them. Toronto’s subsidy program supports severing and capping that sewer connection; the weeping tile water then goes to a sump pit and is pumped outside onto a permeable surface away from the foundation.
This matters because a building-drain device does nothing for water pushed up through the weeping tile into the soil around the foundation if the tile is connected to the sewer downstream of it. The drawings should show the whole path.
For sump discharge, City of Toronto guidance says the pump should empty onto a permeable surface, such as a lawn, garden or gravel, at least two metres from the foundation wall. Where the discharge or new grading changes surface drainage on the lot, a lot grading plan may also be needed. New buildings in Toronto with foundation drainage are covered by the City’s foundation drainage brief requirements.
Is there a subsidy for a backwater valve in Toronto?
Yes. Toronto’s Basement Flooding Protection Subsidy Program covers part of the invoiced cost of installing or replacing backwater valves (up to two) and alarms for owners of single-family, duplex, triplex and fourplex homes. A building permit, an inspection before the valve is covered, and a City-licensed contractor are conditions.
The City expanded the program on May 1, 2026, for eligible work completed on or after November 12, 2025. Other conditions listed on the City’s page (modified November 6, 2026) include:
- the downspouts must be disconnected from the City sewer, or the property must have an exemption;
- front yard paved areas, including parking pads, must comply with the zoning by-law;
- the application must be made within two years of the installation;
- the contractor and any subcontractors must hold a valid City of Toronto business licence at the time of the work, and original paid invoices are required;
- an application does not guarantee a subsidy; funding is first come, first served and subject to the City’s annual budget.
The subsidy maximums and the eligible work change from time to time, so check the City’s page before work starts. Other municipalities in the GTA run their own programs, or none.
Who designs and who installs a backwater valve?
On a permit project, the plumbing designer or engineer decides where valves go and shows them on the drawings; a licensed plumber or drain contractor installs them under the permit; the municipal inspector checks the work. Elmid Design Inc. prepares the design and drawings and does not install valves or do plumbing work.
For Toronto’s subsidy, the City lists the contractor licences accepted for this work: Plumbing Contractor, Plumbing and Heating Contractor, and Drain Contractor. A building renovator licence covers sump pumps and pipe severance but not this work.
Where this is the only work in a one- or two-unit Toronto house, no plans are needed and the plumber usually handles the permit. Engineering drawings add value when the valve is part of a basement renovation, a second unit, an addition or a commercial or multi-unit building.
What does a backwater valve not protect against?
A backwater valve only stops sewage flowing back through the drain it is installed on. It does not stop surface water entering through window wells, doors or walkouts, groundwater seeping through cracks, or a failed sump pump. Those risks are handled by lot grading, downspout routing, foundation drainage and the sump system.
It also needs upkeep: debris can hold its flap open. A licensed plumber’s assessment shows how the house is actually connected before anything is designed.
How much does a backwater valve cost?
Costs depend on the house: drain depth, slab and finishes, access, the number of valves, and whether the work is part of a larger renovation. Installation is priced by your plumber or drain contractor. For the drawings, Elmid prepares a written proposal after reviewing the scope; consultation and quotes are free.
Toronto’s subsidy, where it applies, covers part of the invoiced installation cost; the City’s page states the current limits.
What should you send for basement plumbing drawings?
To prepare a proposal and then the drawings, Elmid usually asks for:
- the property address and municipality, and whether the house has, or will have, a second unit;
- photos of the basement, the floor drain, the main cleanout and where the sewer leaves the house;
- any existing drawings, a survey, or a previous plumbing permit;
- the fixtures you plan to add or move, such as a bathroom, laundry or kitchenette;
- any history of sewer backup or flooding, and whether downspouts and weeping tiles are connected to the sewer;
- a plumber’s assessment, if you already have one.
Areas we serve
Elmid Design Inc. prepares building permit drawings, plumbing design and residential plumbing plans in Toronto and across the Greater Toronto Area, including York, Peel, Halton and Durham regions, and in other Ontario municipalities, depending on project scope and availability.
Related articles
- Toronto plumbing permit guide: drawings and inspections
- Residential plumbing plans in Ontario
- Foundation drainage brief in Toronto
Sources
- Government of Ontario, 2024 Building Code Compendium, Part 7: Plumbing (O. Reg. 163/24), Article 7.4.6.4 Protection from Backflow, page modified October 20, 2026, accessed November 23, 2026.
- City of Toronto, Backwater Valve permit application guide, modified July 14, 2026, accessed November 23, 2026.
- City of Toronto, Basement Flooding Protection Subsidy Program, modified November 6, 2026, accessed November 23, 2026.
- City of Markham, Builder Tip No. 108: Protection From Backflow, January 1, 2025 (updated to the 2024 OBC), accessed November 23, 2026.
This article is general information for Ontario, not design advice for a specific property. Permit routes, subsidy programs and local requirements differ by municipality; confirm them with your municipality’s building department before work starts.